DURAFORM PA AND GF
Create durable, high-quality, fully testable parts with SLS
system.
Use DuraForm materials for:
-
Form, fit/snap-fit, and functional testing
-
In vivo testing
-
Durable patterns for sandcasting & silicone tooling
-
Production parts.
Benefits
-
Durable parts without tooling
-
Heat and chemical resistant
-
Machinable, weldable, readily-joined-mechanically or with
other adhesives
-
Excellent surface quality
-
High feature definition and detail
-
High durability and stability
-
USP Level VI certified; sterilized in an autoclave (PA
only)
DuraForm PA &
GF Materials Typical Properties
| Powder Properties |
Units |
Test Method |
PA |
GF |
|
Density Tap |
g/cm3 |
ASTM D4164 |
0.59 |
0.84 |
| Particle size average(1) |
µm |
Laser Diffraction |
58 |
48 |
| Particle size Range(1) 90% |
µm |
Laser Diffraction |
25-92 |
10-96 |
| Specific Gravity 200C |
|
ASTM D792 |
0.97 |
1.40 |
| Moisture Absorption 230C |
% |
ASTM D570 |
0.41 |
0.30 |
| Thermal Properties |
Units |
Test Method |
PA |
GF |
| Melting point: Tm |
0C |
DSC |
184 |
185 |
| DTUL, 0.45 MPa |
0C |
ASTM D648 |
177 |
175 |
| DTUL, 1.82 MPa |
0C |
ASTM D648 |
86 |
110 |
| Mechanical Properties |
Units |
Test Method |
PA |
GF |
| Tensile Strength |
MPa |
ASTM D638 |
44 |
38.1 |
| Tensile Modulus |
MPa |
ASTM D638 |
1600 |
5910 |
| Tensile Elongation at Break |
% |
ASTM D638 |
9 |
2 |
| Flexural Modulus |
MPa |
ASTM D790 |
1285 |
3300 |
| Impact Strength Notched Izod |
J/m |
ASTM D256 |
214 |
96 |
| Impact Strength Unnotched Izod |
J/m |
ASTM D256 |
428 |
101 |
| Surface Finish |
Units |
Test Method |
PA |
GF |
| Upper Facing As processed, Ra |
µm |
|
8.5 |
6.2 |
| Upper Facing After finishing, Ra |
µm |
|
0.13 |
1.0 |
| Chemical Resistance |
| Alkalines, hydrocarbons, fuels & solvents |
| Electrical Properties |
Units |
Test Method |
PA |
GF |
| Volume Resistivity 220C, 50% RH, 500V |
ohm x cm |
ASDM D257-93 |
3.1 X 1014 |
2.0E X 1014 |
| Surface Resistivity 220C, 50% RH, 500V |
ohm x cm |
ASDM D257-93 |
3.1 X 1014 |
2.3E X 1014 |
| Dielectric Constant 220C, 50% RV, 500V 1000Hz |
|
D150-95 |
2.9 |
3.7 |
| Dielectric Strength 220C, 50% RV, in air,5V
V/sc |
v/mm |
D149-95a |
1.6 X 1014 |
1.5 E X 1014 |
| Comparative Tracking Index |
V |
D5288-92 and/or IEC standard 112 |
585, TI-Cu<1mm depth |
TBD |
(1) Results were based on volume distribution of
particles.
this is text meant just to take up lots of space at the bottom of the page, so that if
there is only a table or something in the content part of this page, the content still
takes up the majority of the screen. if there is not any text here, then sometimes there
will be just a table here, and the left navigation bar to the left will be kinda wide...
|